ModelDescriptionSoftware Model Number
DFUW, DUWC, VUWC24 inch Wine Cellar11
DFUR, DUAR, VUAR24 inch Beverage Center21
DFRD, DURD, VURD24 inch Refrigerated Drawers16
Viking Refrigerator Common Problems
Viking Refrigerator Common Problems

Viking Refrigerator Diagnostic Information

Remedy Diagnostics Establishing allows you to acknowledge the firmware and also software application variants, assessment condition of “design specific” system parts as well as additionally sensors, along with modification state of parts where appropriate (i.e.– compressor on/off, and so forth.).

Making It Possible For Remedy Mode: To permit Option Setup, press in addition to hold the “WARMER” switch while pushing the “COLDER” button four times within 5 seconds.

You can not make it possible for Service Setting while in Establish Mode.– All system features will certainly continue to be in their existing state while in Service Setting.
Alarms are impaired throughout Solution Setting and reset after exiting Option Setup.
Service Setup will automatically disable after 5 (5) minutes of no keypad entrance
After entering Service Setting, the first number that you will certainly see recommends the software program variation number for the particular unit you are servicing. As an example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the really first number you will absolutely see is 11. See chart below for matching style and also software program application suggestion.

The 2nd number you will absolutely see recommends the software application variation launch. As an example, if you see 44 on the display screen panel it shows software program variation 4.4.

Diagnostics:
While in Service Setting, press the “COLLECTION” button to tip with Tests 0-9. The first number of the display will disclose the examination number. The 2nd figure reveals the present state of each part on trial as well as likewise is revealed as “1” jumping on, CLOSED, or SHORTED in addition to “0” being OFF or OPEN. Tests 0 as well as 1 reveal an open or shorted problem spotted at the noticing device inputs. Examinations 2 through 6 allow you to change whole lots ON with the “WARMER” switch along with OFF with the “COLDER” switch. Assessments 7 via 9 validate state adjustment of the door changes and/or magnetic reed sensing unit. The part assessments readily available are defined in Readily available Part Evaluations chart.

PROBLEMPOSSIBLE CAUSEWHAT TO DO
Freezer control and lights are on, but compressor is not operatingRefrigerator is in defrost modeNormal operation Wait 40 minutes to see if compressor restarts.