Model | Description | Software Model Number |
DFUW, DUWC, VUWC | 24 inch Wine Cellar | 11 |
DFUR, DUAR, VUAR | 24 inch Beverage Center | 21 |
DFRD, DURD, VURD | 24 inch Refrigerated Drawers | 16 |
Viking Fridge Diagnostic Details
Service Diagnostics Establishing permits you to recognize the firmware as well as software application variants, examination condition of “version particular” system components and also sensing units, as well as adjustment state of parts where applicable (i.e.– compressor on/off, and so on.).
Enabling Service Mode: To allow Remedy Setup, press in addition to hold the “WARMER” switch while pressing the “COLDER” button four times within 5 seconds.
You can not make it feasible for Solution Establishing while in Establish Setting.– All system functions will certainly stay in their existing state while in Service Setting.
Alarms are impaired throughout Service Setup and reset after leaving Remedy Setup.
Service Setup will automatically disable after 5 (5) mins of no keypad entrance
After getting in Service Setting, the very first number that you will certainly see recommends the software application variation number for the particular system you are servicing. For example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the very first number you will absolutely see is 11. See graph listed below for matching design and software application suggestion.
The second number you will definitely see suggests the software version launch. For instance, if you see 44 on the display screen panel it suggests software application version 4.4.
Diagnostics:
While in Service Setting, press the “COLLECTION” switch to tip with Examinations 0-9. The initial figure of the display will reveal the exam number. The second figure shows the current state of each element on trial and likewise is revealed as “1” getting on, CLOSED, or SHORTED in addition to “0” being OFF or OPEN. Examinations 0 and also 1 disclose an open or shorted problem found at the sensing unit inputs. Examinations 2 via 6 allow you to transform whole lots ON with the “WARMER” button as well as OFF with the “COLDER” switch. Examinations 7 through 9 validate state change of the door switches over and/or magnetic reed sensing unit. The component examinations readily offered are defined in Available Part Exams chart.
PROBLEM | POSSIBLE CAUSE | WHAT TO DO |
Ice forms in inlet tube to ice maker | Water pressure is low | Water pressure is low between 35 – 100 pounds per square inch. A minimum pressure of 35 pounds per square inch is recommended for refrigerators with water filters. |
Freezer temperature is too high. | Adjust freezer controls. Freezer is recommended to be approximately 0oF (-18oC) |