Viking Refrigerator Common Problems
Viking Refrigerator Common Problems

Viking Refrigerator Diagnostic Details

Solution Diagnostics Setting allows you to recognize the firmware as well as software program application variants, evaluation problem of “design particular” system elements as well as likewise sensing units, along with change state of parts where suitable (i.e.– compressor on/off, and so forth.).

Enabling Solution Setting: To allow Service Setting, press along with hold the “WARMER” button while pressing the “COLDER” button four times within 5 seconds.

You can not make it possible for Service Setting while in Establish Setting.– All system features will continue to be in their existing state while in Service Setting.
Alarms are impaired during Service Setup as well as reset after exiting Service Setup.
Option Setting will automatically disable after 5 (5) minutes of no keypad entrance
After entering Service Setting, the very first number that you will definitely see recommends the software application version number for the particular system you are servicing. For example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the really first number you will definitely see is 11. See chart listed below for matching layout and also software program application recommendation.

The second number you will definitely see suggests the software application variation release. For example, if you see 44 on the display screen panel it shows software application variation 4.4.

Diagnostics:
While in Service Setup, press the “COLLECTION” button to tip with Tests 0-9. The first figure of the screen will certainly disclose the examination number. The 2nd number reveals the existing state of each component under examination and likewise is shown as “1” hopping on, CLOSED, or SHORTED along with “0” being OFF or OPEN. Examinations 0 as well as 1 disclose an open or shorted issue found at the sensing system inputs. Examinations 2 via 6 enable you to transform lots ON with the “WARMER” switch along with OFF with the “COLDER” switch. Examinations 7 with 9 validate state adjustment of the door switches over and/or magnetic reed sensor. The part exams conveniently offered are defined in Readily available Element Examinations chart.

PROBLEMPOSSIBLE CAUSEWHAT TO DO
MeatSavor drawer temperature is too warmControl settings are too low.See p 5 to properly adjust controls.