Appointment
ModelDescriptionSoftware Model Number
DFUW, DUWC, VUWC24 inch Wine Cellar11
DFUR, DUAR, VUAR24 inch Beverage Center21
DFRD, DURD, VURD24 inch Refrigerated Drawers16
Viking Refrigerator Common Problems
Viking Refrigerator Common Problems

Viking Refrigerator Diagnostic Information

Remedy Diagnostics Establishing permits you to acknowledge the firmware and software application variants, examination condition of “model particular” system parts and also sensing units, along with adjustment state of components where appropriate (i.e.– compressor on/off, and so on.).

Allowing Solution Setting: To allow Service Setting, press along with hold the “WARMER” button while pressing the “COLDER” button 4 times within 5 secs.

You can deficient feasible for Solution Establishing while in Establish Setting.– All system functions will certainly continue to be in their existing state while in Service Setting.
Alarm systems are impaired during Service Setting and reset after leaving Service Setting.
Option Setting will instantly disable after 5 (5) minutes of no keypad entrance
After getting in Solution Mode, the first number that you will absolutely see recommends the software application variation number for the particular unit you are servicing. As an example, if you are servicing a 24 inch wine rack (DFUW, DUWC, VUWC), the really first number you will definitely see is 11. See graph below for matching layout as well as software program application referral.

The 2nd number you will absolutely see suggests the software application version release. For example, if you see 44 on the display screen panel it indicates software application variation 4.4.

Diagnostics:
While in Service Setting, press the “COLLECTION” switch to tip with Examinations 0-9. The first digit of the screen will disclose the evaluation number. The second number shows the existing state of each element on trial and additionally is shown as “1” hopping on, CLOSED, or SHORTED as well as “0” being OFF or OPEN. Examinations 0 and also 1 reveal an open or shorted issue identified at the picking up device inputs. Examinations 2 with 6 allow you to change lots ON with the “WARMER” switch along with OFF with the “COLDER” button. Examinations 7 via 9 validate state change of the door switches over and/or magnetic reed sensor. The component examinations conveniently available are specified in Available Component Exams graph.

SOUNDPOSSIBLE CAUSESOLUTION
BuzzingIce maker water valve hookup buzzes when ice maker fills with water.Normal operation